2025/02/14 ENABLE GAS TRANSMISSION, LLC PAGE: 1 MVRP3020-53 GAS SAMPLE ANALYSIS MVNX3020 TIME: 15:00:116 Location Gas Day Gravity BTU CO2 % N2 % Oxygen % H2S % Methane % Ethane % Propane % I-Butane % N-Butane % Neo-Pentane % I-Pentane % N-Pentane % Hexanes % N-Heptane % N-Octane % N-Nonane % O2 C1 C2 C3 C5 C6 C7 C8 C9 ----------------------- ---------- ------- ------- ------- ------- -------- ------- --------- -------- --------- ---------- ---------- ------------- ----------- ----------- --------- ----------- ---------- ---------- BAY CHECK GC @ 170610 2025/02/13 0.5863 1.02524 1.1714 00.5456 00.0000 00.0000 94.7861 03.3301 00.1461 00.0067 00.0085 00.0000 00.0018 00.0012 00.0010 00.0007 00.0003 00.0000 CUSTER ST @ LINE AD ST1 2025/02/13 0.5677 1.01105 0.4801 00.6916 00.0000 00.0000 97.7655 01.0068 00.0518 00.0016 00.0022 00.0000 00.0000 00.0000 00.0000 00.0000 00.0000 00.0000 GLENDALE CEGT TO MRT @ 2025/02/13 0.5944 1.04071 0.7520 01.0224 00.0000 00.0000 92.7685 05.1916 00.2255 00.0095 00.0166 00.0000 00.0033 00.0028 00.0035 00.0026 00.0012 00.0000 CHANDLER ST DISCHARGE G 2025/02/13 0.5954 1.04380 0.7371 00.9544 00.0000 00.0000 92.4723 05.6272 00.1872 00.0067 00.0075 00.0000 00.0017 00.0014 00.0019 00.0014 00.0006 00.0000 FM 63 - Columbia GC @ 2 2025/02/13 0.6161 1.06534 0.3154 02.2328 00.0000 00.0000 89.8721 05.8181 01.3252 00.0951 00.1260 00.0000 00.0860 00.0865 00.0201 00.0149 00.0072 00.0000 The information displayed above reflects daily average gas quality readings taken at key locations on the EGT system. The dates shown above are the dates of the readings. The readings are taken daily, and information from such readings is posted on the first day thereafter. If on any reading day there are problems retrieving the data, the last reported readings will remain posted until such time as new readings are obtained. Due to factors such as equipment failure, sample contamination and human error, the information displayed above may not be completely accurate.