2025/02/09 ENABLE GAS TRANSMISSION, LLC PAGE: 1 MVRP3020-53 GAS SAMPLE ANALYSIS MVNX3020 TIME: 15:00:174 Location Gas Day Gravity BTU CO2 % N2 % Oxygen % H2S % Methane % Ethane % Propane % I-Butane % N-Butane % Neo-Pentane % I-Pentane % N-Pentane % Hexanes % N-Heptane % N-Octane % N-Nonane % O2 C1 C2 C3 C5 C6 C7 C8 C9 ----------------------- ---------- ------- ------- ------- ------- -------- ------- --------- -------- --------- ---------- ---------- ------------- ----------- ----------- --------- ----------- ---------- ---------- BAY CHECK GC @ 170610 2025/02/08 0.5862 1.02840 1.0387 00.5468 00.0000 00.0000 94.6977 03.5331 00.1606 00.0080 00.0092 00.0000 00.0023 00.0013 00.0008 00.0006 00.0003 00.0000 CUSTER ST @ LINE AD ST1 2025/02/08 0.5738 1.01365 0.4793 01.1130 00.0000 00.0000 96.5141 01.7719 00.1166 00.0020 00.0027 00.0000 00.0000 00.0000 00.0000 00.0000 00.0000 00.0000 GLENDALE CEGT TO MRT @ 2025/02/08 0.5969 1.04247 0.8590 00.9823 00.0000 00.0000 92.3556 05.5460 00.2237 00.0096 00.0155 00.0000 00.0032 00.0023 00.0011 00.0008 00.0004 00.0000 CHANDLER ST DISCHARGE G 2025/02/08 0.5961 1.04447 0.7623 00.9409 00.0000 00.0000 92.3673 05.7107 00.1952 00.0080 00.0089 00.0000 00.0019 00.0014 00.0013 00.0010 00.0004 00.0000 FM 63 - Columbia GC @ 2 2025/02/08 0.6145 1.06550 0.2720 02.1448 00.0000 00.0000 90.1803 05.6384 01.3190 00.0975 00.1273 00.0000 00.0885 00.0846 00.0223 00.0166 00.0081 00.0000 The information displayed above reflects daily average gas quality readings taken at key locations on the EGT system. The dates shown above are the dates of the readings. The readings are taken daily, and information from such readings is posted on the first day thereafter. If on any reading day there are problems retrieving the data, the last reported readings will remain posted until such time as new readings are obtained. Due to factors such as equipment failure, sample contamination and human error, the information displayed above may not be completely accurate.