2025/01/30 ENABLE GAS TRANSMISSION, LLC PAGE: 1 MVRP3020-53 GAS SAMPLE ANALYSIS MVNX3020 TIME: 15:00:140 Location Gas Day Gravity BTU CO2 % N2 % Oxygen % H2S % Methane % Ethane % Propane % I-Butane % N-Butane % Neo-Pentane % I-Pentane % N-Pentane % Hexanes % N-Heptane % N-Octane % N-Nonane % O2 C1 C2 C3 C5 C6 C7 C8 C9 ----------------------- ---------- ------- ------- ------- ------- -------- ------- --------- -------- --------- ---------- ---------- ------------- ----------- ----------- --------- ----------- ---------- ---------- BAY CHECK GC @ 170610 2025/01/29 0.5891 1.02961 1.1786 00.5389 00.0000 00.0000 94.2142 03.8994 00.1501 00.0063 00.0076 00.0000 00.0016 00.0010 00.0008 00.0006 00.0002 00.0000 CUSTER ST @ LINE AD ST1 2025/01/29 0.5732 1.01028 0.6705 00.9715 00.0000 00.0000 96.7995 01.4769 00.0763 00.0017 00.0030 00.0000 00.0000 00.0000 00.0000 00.0000 00.0000 00.0000 GLENDALE CEGT TO MRT @ 2025/01/29 0.5969 1.04541 0.7628 00.9567 00.0000 00.0000 92.2412 05.7999 00.2089 00.0078 00.0128 00.0000 00.0025 00.0020 00.0023 00.0017 00.0008 00.0000 CHANDLER ST DISCHARGE G 2025/01/29 0.6020 1.05349 0.7459 00.9759 00.0000 00.0000 91.1411 06.9168 00.2026 00.0065 00.0067 00.0000 00.0013 00.0009 00.0008 00.0006 00.0003 00.0000 FM 63 - Columbia GC @ 2 2025/01/29 0.6125 1.06257 0.2729 02.1271 00.0000 00.0000 90.5677 05.3001 01.2862 00.0978 00.1268 00.0000 00.0891 00.0869 00.0212 00.0158 00.0077 00.0000 The information displayed above reflects daily average gas quality readings taken at key locations on the EGT system. The dates shown above are the dates of the readings. The readings are taken daily, and information from such readings is posted on the first day thereafter. If on any reading day there are problems retrieving the data, the last reported readings will remain posted until such time as new readings are obtained. Due to factors such as equipment failure, sample contamination and human error, the information displayed above may not be completely accurate.