2025/01/18 ENABLE GAS TRANSMISSION, LLC PAGE: 1 MVRP3020-53 GAS SAMPLE ANALYSIS MVNX3020 TIME: 15:00:148 Location Gas Day Gravity BTU CO2 % N2 % Oxygen % H2S % Methane % Ethane % Propane % I-Butane % N-Butane % Neo-Pentane % I-Pentane % N-Pentane % Hexanes % N-Heptane % N-Octane % N-Nonane % O2 C1 C2 C3 C5 C6 C7 C8 C9 ----------------------- ---------- ------- ------- ------- ------- -------- ------- --------- -------- --------- ---------- ---------- ------------- ----------- ----------- --------- ----------- ---------- ---------- BAY CHECK GC @ 170610 2025/01/17 0.5901 1.03290 1.0425 00.6389 00.0000 00.0000 93.9070 04.2104 00.1775 00.0077 00.0104 00.0000 00.0020 00.0013 00.0009 00.0006 00.0003 00.0000 CUSTER ST @ LINE AD ST1 2025/01/17 0.5743 1.01437 0.4373 01.1851 00.0000 00.0000 96.3241 01.9571 00.0917 00.0018 00.0027 00.0000 00.0000 00.0000 00.0000 00.0000 00.0000 00.0000 GLENDALE CEGT TO MRT @ 2025/01/17 0.5965 1.04480 0.7486 00.9760 00.0000 00.0000 92.2867 05.7651 00.1949 00.0077 00.0127 00.0000 00.0023 00.0019 00.0017 00.0013 00.0006 00.0000 CHANDLER ST DISCHARGE G 2025/01/17 0.5980 1.04883 0.6699 00.9961 00.0000 00.0000 91.8463 06.2962 00.1769 00.0052 00.0054 00.0000 00.0011 00.0008 00.0008 00.0005 00.0002 00.0000 FM 63 - Columbia GC @ 2 2025/01/17 0.6117 1.02525 0.9748 03.2265 00.0000 00.0000 90.6329 03.8825 00.9181 00.0774 00.0857 00.0000 00.0663 00.0580 00.0280 00.0208 00.0101 00.0000 The information displayed above reflects daily average gas quality readings taken at key locations on the EGT system. The dates shown above are the dates of the readings. The readings are taken daily, and information from such readings is posted on the first day thereafter. If on any reading day there are problems retrieving the data, the last reported readings will remain posted until such time as new readings are obtained. Due to factors such as equipment failure, sample contamination and human error, the information displayed above may not be completely accurate.