2025/01/17 ENABLE GAS TRANSMISSION, LLC PAGE: 1 MVRP3020-53 GAS SAMPLE ANALYSIS MVNX3020 TIME: 15:00:146 Location Gas Day Gravity BTU CO2 % N2 % Oxygen % H2S % Methane % Ethane % Propane % I-Butane % N-Butane % Neo-Pentane % I-Pentane % N-Pentane % Hexanes % N-Heptane % N-Octane % N-Nonane % O2 C1 C2 C3 C5 C6 C7 C8 C9 ----------------------- ---------- ------- ------- ------- ------- -------- ------- --------- -------- --------- ---------- ---------- ------------- ----------- ----------- --------- ----------- ---------- ---------- BAY CHECK GC @ 170610 2025/01/16 0.5884 1.03000 1.0959 00.5695 00.0000 00.0000 94.2802 03.8897 00.1459 00.0062 00.0077 00.0000 00.0017 00.0011 00.0007 00.0005 00.0002 00.0000 CUSTER ST @ LINE AD ST1 2025/01/16 0.5734 1.01202 0.5409 01.0838 00.0000 00.0000 96.6194 01.6667 00.0842 00.0019 00.0028 00.0000 00.0000 00.0000 00.0000 00.0000 00.0000 00.0000 GLENDALE CEGT TO MRT @ 2025/01/16 0.5951 1.04239 0.7379 01.0027 00.0000 00.0000 92.5749 05.4548 00.1994 00.0077 00.0132 00.0000 00.0024 00.0020 00.0021 00.0016 00.0007 00.0000 CHANDLER ST DISCHARGE G 2025/01/16 0.5972 1.04688 0.6856 01.0133 00.0000 00.0000 92.0182 06.0962 00.1725 00.0050 00.0053 00.0000 00.0011 00.0008 00.0007 00.0005 00.0002 00.0000 FM 63 - Columbia GC @ 2 2025/01/16 0.6129 1.05932 0.4952 02.0265 00.0000 00.0000 90.6409 05.1720 01.2199 00.0994 00.1217 00.0000 00.0898 00.0836 00.0230 00.0171 00.0083 00.0000 The information displayed above reflects daily average gas quality readings taken at key locations on the EGT system. The dates shown above are the dates of the readings. The readings are taken daily, and information from such readings is posted on the first day thereafter. If on any reading day there are problems retrieving the data, the last reported readings will remain posted until such time as new readings are obtained. Due to factors such as equipment failure, sample contamination and human error, the information displayed above may not be completely accurate.