2024/12/31 ENABLE GAS TRANSMISSION, LLC PAGE: 1 MVRP3020-53 GAS SAMPLE ANALYSIS MVNX3020 TIME: 15:00:121 Location Gas Day Gravity BTU CO2 % N2 % Oxygen % H2S % Methane % Ethane % Propane % I-Butane % N-Butane % Neo-Pentane % I-Pentane % N-Pentane % Hexanes % N-Heptane % N-Octane % N-Nonane % O2 C1 C2 C3 C5 C6 C7 C8 C9 ----------------------- ---------- ------- ------- ------- ------- -------- ------- --------- -------- --------- ---------- ---------- ------------- ----------- ----------- --------- ----------- ---------- ---------- BAY CHECK GC @ 170610 2024/12/30 0.5852 1.02474 1.1456 00.5099 00.0000 00.0000 95.0052 03.1672 00.1472 00.0079 00.0098 00.0000 00.0026 00.0017 00.0011 00.0008 00.0004 00.0000 CUSTER ST @ LINE AD ST1 2024/12/30 0.5804 1.01852 0.5924 01.2759 00.0000 00.0000 95.2429 02.7620 00.1219 00.0021 00.0025 00.0000 00.0000 00.0000 00.0000 00.0000 00.0000 00.0000 GLENDALE CEGT TO MRT @ 2024/12/30 0.5965 1.04421 0.8137 00.9165 00.0000 00.0000 92.3443 05.7002 00.2015 00.0073 00.0100 00.0000 00.0021 00.0014 00.0011 00.0008 00.0004 00.0000 CHANDLER ST DISCHARGE G 2024/12/30 0.5960 1.04501 0.7109 00.9776 00.0000 00.0000 92.3593 05.6990 00.2319 00.0078 00.0082 00.0000 00.0016 00.0011 00.0010 00.0007 00.0003 00.0000 FM 63 - Columbia GC @ 2 2024/12/30 0.5996 1.07333 0.1897 00.4033 00.0000 00.0000 91.5078 07.4470 00.3611 00.0295 00.0387 00.0000 00.0083 00.0050 00.0043 00.0032 00.0015 00.0000 The information displayed above reflects daily average gas quality readings taken at key locations on the EGT system. The dates shown above are the dates of the readings. The readings are taken daily, and information from such readings is posted on the first day thereafter. If on any reading day there are problems retrieving the data, the last reported readings will remain posted until such time as new readings are obtained. Due to factors such as equipment failure, sample contamination and human error, the information displayed above may not be completely accurate.