2022/02/24 ENABLE GAS TRANSMISSION, LLC PAGE: 1
MVRP3020-53 GAS SAMPLE ANALYSIS MVNX3020
TIME: 15:00:149
Location Gas Day Gravity BTU CO2 % N2 % Oxygen % H2S % Methane % Ethane % Propane % I-Butane % N-Butane % Neo-Pentane % I-Pentane % N-Pentane % Hexanes % N-Heptane % N-Octane % N-Nonane %
O2 C1 C2 C3 C5 C6 C7 C8 C9
----------------------- ---------- ------- ------- ------- ------- -------- ------- --------- -------- --------- ---------- ---------- ------------- ----------- ----------- --------- ----------- ---------- ----------
MAGNOLIA CHECK GC @ 769 2022/02/23 0.5857 1.02422 1.3327 00.3022 00.0000 00.0000 95.6765 02.1682 00.3546 00.0605 00.0562 00.0000 00.0165 00.0092 00.0109 00.0081 00.0039 00.0000
BAY CHECK GC @ 170610 2022/02/23 0.5815 1.01641 1.3420 00.3616 00.0000 00.0000 95.9997 02.1249 00.1376 00.0098 00.0115 00.0000 00.0030 00.0032 00.0035 00.0017 00.0008 00.0000
CUSTER ST @ LINE AD ST1 2022/02/23 0.5641 1.00856 0.4678 00.5198 00.0000 00.0000 98.4852 00.5020 00.0229 00.0010 00.0010 00.0000 00.0000 00.0000 00.0000 00.0000 00.0000 00.0000
GLENDALE CEGT TO MRT @ 2022/02/23 0.5846 1.03286 0.6002 00.7963 00.0000 00.0000 94.6025 03.7927 00.1713 00.0104 00.0154 00.0000 00.0033 00.0026 00.0023 00.0017 00.0008 00.0000
CHANDLER ST DISCHARGE G 2022/02/23 0.5868 1.03091 0.7402 00.9058 00.0000 00.0000 94.3805 03.7210 00.1987 00.0046 00.0066 00.0000 00.0155 00.0142 00.0059 00.0044 00.0021 00.0000
COLUMBIA GULF FROM CP @ 2022/02/23 0.5852 1.01723 1.7127 00.0948 00.0000 00.0000 95.9197 01.9341 00.2237 00.0589 00.0285 00.0000 00.0116 00.0041 00.0054 00.0040 00.0019 00.0000
FM 63 - Columbia GC @ 2 2022/02/23 0.5795 1.02444 0.6098 00.8059 00.0000 00.0000 95.6454 02.7560 00.1410 00.0106 00.0149 00.0000 00.0039 00.0028 00.0043 00.0032 00.0015 00.0000
The information displayed above reflects daily average gas quality readings
taken at key locations on the EGT system. The dates shown above are the
dates of the readings. The readings are taken daily, and information from such
readings is posted on the first day thereafter. If on any reading day there
are problems retrieving the data, the last reported readings will remain
posted until such time as new readings are obtained. Due to factors such as
equipment failure, sample contamination and human error, the information
displayed above may not be completely accurate.